Watermeter Sensus DN 20mm


Watermeter Sensus DN 20mm Fully dry dial meter with no gear reduction in the wet chamberWear resistant tungsten carbide/sapphire bearing,Magnetic coupling protected against magnetite,Pulse sender safe from interface,Easy to repair construction with external regulation

DESCRIPTION

The flow sensors AN 130 are multi-jet dry dial vane impeller hot water meters, suitable for installing in central heating and cooling systems and remote warning systems. With their built-in pulse sender they are approved as low sensors for heating meters according the European measuring instruments directive (MID) 2004/22/EG

Versions for horizontal, rising and falling flow directions with screwings (PN 16) or flanges (horizontal flow, PN 25) are available.

TECHNICAL DATA : Watermeter Sensus DN 20mm

  • Display : 00000.000 m³
  • Working pressure : 16
  • Working temperature : 10…130℃
  • Accuracy class : Class 2 or 3
  • Pulse sender : Reed switch permanently installed
  • Cable length : 2 m
  • Load capacity : max.0.1A, max. 28 V
  • Contact resistance : max 105 Ohm
  • Pulse value : 10 litres
  • Casing : Brass, painted
  • Impeller : Plastic
  • Impeller Cup : Plastic
  • Bearing Pin : Tungsten Carbide
  • Impeller bearing : Sapphire
  • Magnetic Coupling : Ceramic permanent magnets

PERFORMANCE DATA

  • Nominal size : 1.5
  • Continuous loading : 1.5 m³/h
  • Max. Flow rate (short-term) : 3 m³/h
  • Ratio : 1 : 50
  • Minimum flow rate : 30 l/h
  • Pressure loss at : 0.11 bar
  • Flow rate at 1 bar pressure loss : 4.7 m³/h

DIMENSION AND WEIGHTS 

  • Size marking : 1.5 m³
  • Nominal Connection size : 20 mm
  • Installed length : 190 mm
  • Height : 157
  • Flange diameter : 105 mm
  • Width : 95 mm
  • Weight : 3.5 kg