A versatile flow meter for oil, heavy oil and many other oil-like liquids. It is used for efficient consumption measurement of heat burners and various combustion engines. A reliable solution for any application where oil is consumed.
Features :
- State-of-the-art design
- Electronic counter, mass flow, volume flow indication, analog, multiple output signals
- Integrated temperature sensors
- No straight inlets or outlets required
- Independet of viscosity and temperature
- High vibration resistance
- Optional : Metrological type approvals
- Auto medium switch over by temperature
Benefits :
- Mass Flow measurements
- Highly flexible mounting with very small space requirements
- Reliable monitoring and flexible control of the system
- Accurate measurements
- A reliable solution with everything from a single supplier
- Simplifies consumption optimizing
Operating principle :
Function :
CONTOIL flow meters work on the volumetric principle rotary piston meters (positive displacement meters).
The main features of this measuring principle are large measuring range, high acuracy, suitability for high viscosities and independence from power supply;flow disturbances do not influence proper operation.
Leading manufacturrs of oil burners and operators of hearing systems, ships or diesel engines relyon CONTOIL fuel oil meters – and good reasons.
Technical Data :
• with electronic display of total volume,resettable volume and flow rate,units: litres or US gallons 2)
• fuel oil meter with threaded or flanged connection
• for mounting in a horizontal,vertical or inclined position
Option:with inductive INA pulser
Versions available on request:
• different flange drillings,such as ANSI,JIS
VZO 15 | VZO 20 | VZO 25 | VZO 40 | VZO 50 | |
Nominal Diameter | 15 mm / 1/2″ | 20 mm / 3/4″ | 25 mm / 1″ | 40 mm / 1.5″ | 50 mm / 2″ |
Installation Length | 165 mm | 165 mm | 190 mm | 300 mm | 350 mm |
Connection Threads | None, DIN 2501 Flanged | None, DIN 2501 Flanged | None, DIN 2501 Flanged | None, DIN 2501 Flanged | None, DIN 2501 Flanged |
Nominal Pressure – Threaded | 16 Bar | 16 Bar | 16 Bar | 16 Bar | 16 Bar |
Nominal Pressure – Flanged | 25 Bar Or 40 Bar | 25 Bar Or 40 Bar | 25 Bar Or 40 Bar | 25 Bar Or 40 Bar | 25 Bar Or 40 Bar |
Maximum Temperature | +130 or +180 Celcius | +130 or +180 Celcius | +130 or +180 Celcius | +130 or +180 Celcius | +130 or +180 Celcius |
Maximum Flow Rate | 600 lph | 1,500 lph | 3,000 lph | 9,000 lph | 30,000 lph |
Continuous Flow Rate | 400 lph | 1,000 lph | 2,000 lph | 6,000 lph | 20,000 lph |
Minimum Flow Rate | 10 lph | 30 lph | 75 lph | 225 lph | 750 lph |
Approx Starting Flowrate | 4 lph | 12 lph | 30 lph | 90 lph | 300 lph |
Maximum Permissible Error | ±1.0% of reading | ±1.0% of reading | ±1.0% of reading | ±1.0% of reading | ±1.0% of reading |
Smallest Readable Amount | 0.01 Litres | 0.1 Litres | 0.1 Litres | 0.1 Litres | 1 Litre |
Registration Capacity | 1,000 Litres | 10,000 Litres | 10,000 Litres | 10,000 Litres | 100,000 Litres |
Safety Filter Mesh Size | 400 Micron | 400 Micron | 400 Micron | 800 Micron | 800 Micron |
Dirt Filter Mesh Size | 250 Micron | 400 Micron | 400 Micron | 600 Micron | 600 Micron |
Volume of Measuring Chamber | 12 cm3 | 36 cm3 | 100 cm3 | 330 cm3 | 1,200 cm3 |
Ingress Protection | IP65 | IP65 | IP65 | IP65 | IP65 |
VZO 15 | VZO 20 | VZO 25 | VZO 40 | VZO 50 | |
Length | 165 mm | 165 mm | 190 mm | 300 mm | 350 mm |
Width | 105 mm | 105 mm | 130 mm | 210 mm | 280 mm |
Height 130c Type | 106 mm | 115 mm | 142 mm | 235 mm | 291 mm |
Height 180c Type | 147 mm | 156 mm | 183 mm | 235 mm | 291 mm |
Weight – PN25 Flanged | 3.8 kg | 4.5 kg | 7.5 kg | 20.3 kg | 41.0 kg |
Weight – PN40 Flanged | 4.4 kg | 5.5 kg | 7.8 kg | 20.5 kg | 42.0 kg |
Display | Temp Max | Pressure Max | Pulser Type | Litres Per Pulse | Pulses Per Litre | Part Number DN15 | Part Number DN20 | Part Number DN25 | Part Number DN40 | Part Number DN50 |
Local | 130 Celcius | 25 Bar | – | – | – | VZO 15 FL 130/25 | VZO 20 FL 130/25 | VZO 25 FL 130/25 | VZO 40 FL 130/25 | VZO 50 FL 130/25 |
Local | 130 Celcius | 25 Bar | Reed Switch | 0.1 | 10 | VZO 15 FL 130/25-RV 0.1 | – | – | – | – |
Local | 130 Celcius | 25 Bar | Reed Switch | 1 | 1 | VZO 15 FL 130/25-RV 1 | VZO 20 FL 130/25-RV 1 | VZO 25 FL 130/25-RV 1 | VZO 40 FL 130/25-RV 1 | – |
Local | 130 Celcius | 25 Bar | Reed Switch | 10 | – | – | – | VZO 40 FL 130/25-RV 10 | VZO 50 FL 130/25-RV 10 | |
Local | 130 Celcius | 25 Bar | Reed Switch | 100 | – | – | – | – | VZO 50 FL 130/25-RV 100 | |
Local | 130 Celcius | 25 Bar | Inductive Pulser | 0.01 | 100 | VZO 15 FL 130/25-IN 0.01 | VZO 20 FL 130/25-IN 0.01 | – | – | – |
Local | 130 Celcius | 25 Bar | Inductive Pulser | 0.1 | 10 | – | – | VZO 25 FL 130/25-IN 0.1 | VZO 40 FL 130/25-IN 0.1 | – |
Local | 130 Celcius | 25 Bar | Inductive Pulser | 1 | 1 | – | – | – | – | VZO 50 FL 130/25-IN 1 |
Local | 180 Celcius | 25 Bar | – | – | – | VZO 15 FL 180/25 | VZO 20 FL 180/25 | VZO 25 FL 180/25 | VZO 40 FL 180/25 | VZO 50 FL 180/25 |
Local | 180 Celcius | 25 Bar | Reed Switch | 0.1 | 10 | VZO 15 FL 180/25-RV 0.1 | – | – | – | – |
Local | 180 Celcius | 25 Bar | Reed Switch | 1 | 1 | VZO 15 FL 180/25-RV 1 | VZO 20 FL 180/25-RV 1 | VZO 25 FL 180/25-RV 1 | VZO 40 FL 180/25-RV 1 | – |
Local | 180 Celcius | 25 Bar | Reed Switch | 10 | – | – | – | – | VZO 50 FL 180/25-RV 10 | |
Local | 180 Celcius | 25 Bar | Inductive Pulser | 0.01 | 100 | VZO 15 FL 180/25-IN 0.01 | VZO 20 FL 180/25-IN 0.01 | – | – | |
Local | 180 Celcius | 25 Bar | Inductive Pulser | 0.1 | 10 | – | – | VZO 25 FL 180/25-IN 0.1 | VZO 40 FL 180/25-IN 0.1 | |
Local | 180 Celcius | 25 Bar | Inductive Pulser | 1 | 1 | – | – | – | – | VZO 50 FL 180/40-IN 1 |
Local | 180 Celcius | 40 Bar | – | – | – | VZO 15 FL 180/40 | VZO 20 FL 180/40 | VZO 25 FL 180/40 | VZO 40 FL 180/40 | VZO 50 FL 180/40 |
Local | 180 Celcius | 40 Bar | Reed Switch | 0.1 | 10 | VZO 15 FL 180/40-RV 0.1 | – | – | – | – |
Local | 180 Celcius | 40 Bar | Reed Switch | 1 | 1 | VZO 15 FL 180/40-RV 1 | VZO 20 FL 180/40-RV 1 | VZO 25 FL 180/40-RV 1 | VZO 40 FL 180/40-RV 1 | – |
Local | 180 Celcius | 40 Bar | Reed Switch | 10 | – | – | – | – | VZO 50 FL 180/40-RV 10 | |
Local | 180 Celcius | 40 Bar | Inductive Pulser | 0.01 | 100 | VZO 15 FL 180/40-IN 0.01 | VZO 20 FL 180/40-IN 0.01 | – | – | |
Local | 180 Celcius | 40 Bar | Inductive Pulser | 0.1 | 10 | – | – | VZO 25 FL 180/40-IN 0.1 | VZO 40 FL 180/40-IN 0.1 | |
Local | 180 Celcius | 40 Bar | Inductive Pulser | 1 | 1 | – | – | – | – | VZO 50 FL 180/40-IN 1 |
Display | Temp Max | Pressure Max | Pulser Type | Litres Per Pulse | Pulses Per Litre | Part Number DN15 | Part Number DN20 | Part Number DN25 | Part Number DN40 | Part Number DN50 |
Local | 130 Celcius | 25 Bar | – | – | – | 92044 | 92049 | 92059 | 92005 | 92007 |
Local | 130 Celcius | 25 Bar | Reed Switch | 0.1 | 10 | 92045 | – | – | – | – |
Local | 130 Celcius | 25 Bar | Reed Switch | 1 | 1 | 92046 | 92050 | 92060 | 92020 | – |
Local | 130 Celcius | 25 Bar | Reed Switch | 10 | – | – | – | 92021 | 92024 | |
Local | 130 Celcius | 25 Bar | Reed Switch | 100 | – | – | – | – | 92025 | |
Local | 130 Celcius | 25 Bar | Inductive Pulser | 0.01 | 100 | 91910 | 91903 | – | – | – |
Local | 130 Celcius | 25 Bar | Inductive Pulser | 0.1 | 10 | – | – | 91914 | 91907 | – |
Local | 130 Celcius | 25 Bar | Inductive Pulser | 1 | 1 | – | – | – | – | 91909 |
Local | 180 Celcius | 25 Bar | – | – | – | 92250 | 92258 | 92264 | 92274 | 92280 |
Local | 180 Celcius | 25 Bar | Reed Switch | 0.1 | 10 | 92251 | – | – | – | – |
Local | 180 Celcius | 25 Bar | Reed Switch | 1 | 1 | 92252 | 92259 | 92265 | 92275 | – |
Local | 180 Celcius | 25 Bar | Reed Switch | 10 | – | – | – | – | 92281 | |
Local | 180 Celcius | 25 Bar | Inductive Pulser | 0.01 | 100 | 92253 | 92260 | – | – | |
Local | 180 Celcius | 25 Bar | Inductive Pulser | 0.1 | 10 | – | – | 92266 | 92276 | |
Local | 180 Celcius | 25 Bar | Inductive Pulser | 1 | 1 | – | – | – | – | 92282 |
Local | 180 Celcius | 40 Bar | – | – | – | 92254 | 92261 | 92267 | 92277 | 92283 |
Local | 180 Celcius | 40 Bar | Reed Switch | 0.1 | 10 | 92255 | – | – | – | – |
Local | 180 Celcius | 40 Bar | Reed Switch | 1 | 1 | 92256 | 92262 | 92268 | 92278 | – |
Local | 180 Celcius | 40 Bar | Reed Switch | 10 | – | – | – | – | 92284 | |
Local | 180 Celcius | 40 Bar | Inductive Pulser | 0.01 | 100 | 92257 | 92263 | – | – | |
Local | 180 Celcius | 40 Bar | Inductive Pulser | 0.1 | 10 | – | – | 92269 | 92279 | |
Local | 180 Celcius | 40 Bar | Inductive Pulser | 1 | 1 | – | – | – | – | 92285 |